Question: 

I have just moved into a new home and during the construction I noticed that one of the trusses in the garage was damaged. The web plate had come off in two different locations. I notified the builder and they said they would take care of it. Approximately two weeks after I moved in, I noticed the ceiling in the garage started to sag, so I went into the space above the garage and found the truss was never repaired. I again notified the builder and they sent someone to fix it. I went and looked at the fix and this is where my question comes in.

Question: 

We have been specifying laminated veneer lumber (LVL) beams for some time now. The plans usually state, “Beam to be engineered and supplied by truss manufacturer.” What kind of liability issues do I need to watch out for?

Question: 

How do you avoid floor performance problems?

Question: 

I am a structural engineer designing pool cage structures that are typically attached to the house at the fascia board. Sometimes, the structure is attached where trusses are behind the fascia board and other times there is a framed gable end overhang. Do you know of any information concerning this additional load on the trusses or overhang under design wind loads? Is there a limiting distance on the amount of overhang? I know trusses are designed for certain uplift and the pool cage will add to this uplift at design load, but what about the gable end overhangs?

Question: 

How important is continuous lateral bracing in roof trusses? Is it detrimental to the roof integrity if it is missing?

Question: 

I have a 29 x 72 mobile office with a 2-foot deep wooden truss above the ceiling that a client is required to sprinkler. Is there any way to avoid sprinklering above the gypboard ceiling?

Question: 

We have designed a custom home that needs a good solid floor, with low vibration perceptibility. The system we have specified consists of 2 in. of gypcrete over 1 and 1/8 in. thick plywood or OSB. The floor trusses are 20 in. deep at 16 in. O.C., spanning 31 ft. 6 in. The preliminary truss design shows a double top and bottom chord with a total load deflection of 1.30 in. (l/290) and a live load deflection of 0.65 in. (l/581). The basement ceiling will be 1/2 in. gypboard nailed to the bottom of the trusses.

Question: 

Is there a detailed table for gable studs that gives the maximum length a vertical member can be before a lateral brace is required?

Question: 

What are the qualifications (if any) required to be considered a truss technician?

Question: 

Is it the responsibility of the truss manufacturer to provide a sealed layout drawing for roof trusses?