Field Repairs & Alterations

Question: 

I am a structural engineer designing pool cage structures that are typically attached to the house at the fascia board. Sometimes, the structure is attached where trusses are behind the fascia board and other times there is a framed gable end overhang. Do you know of any information concerning this additional load on the trusses or overhang under design wind loads? Is there a limiting distance on the amount of overhang? I know trusses are designed for certain uplift and the pool cage will add to this uplift at design load, but what about the gable end overhangs?

Question: 

How often are trusses repaired?

Question: 

As a home inspector, I have recently inspected an existing home with an attic truss system installed. Several of the truss web members have been cut away to allow access to an attic-mounted heating system. Can you recommend repairs to a truss with cut web members?

Question: 

How do trussed roofs perform in long-term service? Are there any reports of rusting in the nail plates, rot/insect attack, do-it-yourself modifications, or condensation and ventilation problems in the attic?

Question: 

Can I safely install 3/4 in. T&G, OSB on 2x4 trusses that are 24 in. O.C.? My roof was installed over 5/8 in. plywood without clips that have caused a lot of sagging and the shingles need replacing. I want to “fix” it one time and install architecture type shingles, but the garage is 24 ft. wide and 28 ft. long without any load bearing walls. My concern is the weight on the trusses. 5/8 in. plywood weighs 52 lbs. and the OSB weighs 78 lbs. for each 4 ft. x 8 ft. sheet. The roof will require about 84 4 ft. x 8 ft. sheets to cover, which equals about 2,184 lbs.

Question: 

I have a four-year-old house with glued open-web trusses. Both the truss manufacturer and the builder have admitted to me that the trusses were installed wrong. I have a problem with the suggested repair. I have hired a structural engineer and he suggested installing a 2x10 between each truss and removing the old truss. This would have to take place on both the first and second floors because all the trusses were installed wrong. The manufacturers want to install six strongbacks on each floor, hoping this will tighten them up.

Question: 

I am a structural engineer on a project with a wood trussed roof. I have noticed some variations in the peak height in a run of identical trusses. Do you have any information on tolerances for the final dimensions of manufactured trusses?

Question: 

I need to know how to repair a hole that has been drilled through a truss. In installing the wiring we improperly put the wires through the truss and now need to know the proper way to repair it.

Dan Morris—a field service engineer at Apex Technology—and Kelly LaBlance—a technical manager with Builders FirstSource—are both convinced that developing and maintaining a design QC process has helped their companies. Their expertise in analyzing designs and finding creative solutions to solve or even prevent problems was on display as they guided BCMC attendees through common design mistakes and the issues they cause in the field. 

This presentation provides information on and requirements for truss repairs.