Products

Question: 

We are experiencing problems with bouncy wood floor trusses. I'm wondering what the industry standard is on deflections (live and total load). Also, do you have any ideas on how to decrease the deflection without affecting the profit margin significantly?

Question: 

I am looking for strongback bracing requirements for a 12 in. deep residential floor system with trusses in lengths up to 19 ft. Can the strongback bracing end at a truss without tying into an end wall? For instance, can three trusses of a type be tied together by strongbacks, then the next series of different trusses be tied together without having to be tied back to the previous type of trusses?

Question: 

Some building designers believe that gable end webs need to be L-braced to 90% of the web length, which sounds fine. However, they spec that scissors gable end webs need to be braced to 100% of the web length. That means that in the field they are notching the braces to fit around top and bottom chords – you can imagine how difficult that can be. Is that necessary or even the intent of the web L-bracing?

Question: 

Would you please inform me of the specified requirements of the size and the amount of nail attachments from the truss to the top plate?

Question: 

I am looking for some information regarding black surface mold on lumber. Does it alter the integrity of the lumber stress values? I have a client who wants to use “all dry” lumber for his construction but I do not know if this is really necessary.

Question: 

We have been using Turb-O-Webs for about four months. We are very happy with their performance, although there have been a few ripples along the way. The main thing that concerns me at present is the need for performance documentation and testing data. Do you have anything that will help, or know of people or organizations that could offer assistance?

Question: 

While building a new 2-story home, I found the need to use floor trusses between the 1st and 2nd floors. Is it true that I must also use roof trusses?

Question: 

We are planning to add 1/2 in. cement board and 3/8 in. quarry tile to a kitchen floor. We need to know if the floor trusses will handle the additional weight. The floor trusses are 19.2 in. O.C. and the loading numbers are 40-10-0-5. What do these numbers mean?

Question: 

Is it possible to construct an assembly for ceiling between first and second floors using 2x with few layers of gypsum to obtain a 3-hour fire rating?

Question: 

When you’re selling trusses through a lumberyard and the contractor calls to say that the “trusses don't fit correctly,” who has the ultimate responsibility for the trusses? I argue that the lumberyard is responsible since we have provided them with all the information on how the job was designed, even though they may or may not have passed this information on to the contractor.