Product Performance

Question: 

Can a roof truss penetrate a one-hr. tenant separation wall without having a one-hr. rated ceiling? The building official insists that the 2x4 chords are combustible and nullify the integrity of the one-hr. rated partition that is constructed in an attic above an 8 in. C.M.U. bearing wall. The partition consists of gypsum board attached to 2 x 4 stud framing. The building official insists that a ledger must be attached through the gypsum board to support the trusses each side of the wall. This is almost saying that any rated assembly must have bearing only on other rated assemblies.

Question: 

I was wondering if you have any information or anecdotes relating to the deflection performance of long span scissors trusses? We recently sold a job with 70 ft. long scissors trusses. The customer is in the process of installing the trusses and doesn't like the deflections he is seeing. To make matters worse, the scissors trusses are framing into a valley set (which we provided) that is erected on 35 ft. Howe trusses. The Howe trusses are exhibiting very little deflection. Any ideas?

Question: 

A question has come up concerning sloped roof trusses and fire assembly ratings. Some are reluctant to rely on test results from flat (parallel chord) trusses applied to sloped roof trusses. Do you have any information regarding the suitability of the fire rated ceiling assemblies for sloped roof trusses? Does the “minimum depth” requirement of the parallel chord assembly apply to the minimum depth of a sloped roof truss (i.e., heel height?)

Question: 

Occasionally we deal with truss failures due to impact and or crushing forces such as trees falling onto roof structures. At what point can the truss no longer be repaired? Also, what should an adjuster look for when determining repair-ability? Or should a storm adjuster basically punt and call a consultant for every truss failure?

Question: 

I have been hired by an insurance company to determine the extent of damage to roof trusses exposed to fire. How much fire damage compromises the structural integrity of the truss?

Question: 

Is the truss designer or the building designer responsible for calculating snow drift loads on a roof system?

Question: 

Are there any schematics available on how to horizontally brace a 7/12 pitch roof?

Question: 

The grading rules usually permit some percentage of visually graded lumber to be below grade – I believe it is 5%. ANSI/TPI 1 requires that all lumber used in trusses be of the grade specified by the truss design. A strict interpretation of ANSI/TPI 1 would require that the fabricator cull the 5% that is off grade. What are your thoughts on this?

Question: 

I recall seeing a design recommendation several years ago regarding installation of hanger nails above the neutral axis of the bottom chord of a plated girder truss. The intent was to avoid dumping large loads into the bottom chord, below the neutral axis. Can you tell me where I can find this information?

Question: 

We keep having problems with dry wall joints raising on the vaulted bottom chords in the track homes that we are building. The joints run from front to back of the house and the trusses bear on the side walls. The trusses are mostly 2-point bearing (a few in the front and back of the building are tri-bearing). The trusses span 40 ft. and have a 4/12 pitch with a tile roof. Is it common to have dry wall problems as the trusses deflect? How long should the roof be loaded before hanging sheetrock? Should the heel of the truss be allowed to slide out on the top plate?