Skip to main content
Sign In / Register
Home

SBC Magazine Action Menu

  • Subscribe
  • Contact
  • Advertise

SBC Magazine Main Menu

  • The Magazine
  • Industry News
  • Energy Efficiency News
  • Framing News
  • Member Only News
  • Podcast
  • Sponsors

SBCA Logo

Construction

Warning Poster Caution Notes

Question: 

We are concerned with SBCA’s BCSI-B1 Summary Sheet which under “Notes” makes a disclaimer. Our concern is if there would be an accident with our trusses and we point out that the bracing was not placed correctly according to SBCA documentation, which is sent with every job. If the accident goes to court, how will our attorney respond when the opposing attorney points out the disclaimer, which infers that the bracing we recommend must be flawed, otherwise it would not be disclaimed?

Strongback Bracing

Question: 

I am looking for strongback bracing requirements for a 12 in. deep residential floor system with trusses in lengths up to 19 ft. Can the strongback bracing end at a truss without tying into an end wall? For instance, can three trusses of a type be tied together by strongbacks, then the next series of different trusses be tied together without having to be tied back to the previous type of trusses?

Fire Rating For Truss Assemblies Built With 2x3 Lumber

Question: 

Are there any published studies or guidelines on the fire rating of floor trusses built with 2x3 lumber?

Gable End Bracing

Question: 

Is there a detailed table for gable studs that gives the maximum length a vertical member can be before a lateral brace is required?

Truss Storage Responsibilities

Question: 

We have a customer that bought trusses in June. The trusses were shipped [ and one month later are] being set. The chords have weathered and bowed. What is the industry standard for dealing with this problem? What is our liability in this situation? We were not aware of any delays on the customer’s part and shipped as requested. Note: These trusses are 62 ft. scissor trusses.

Bottom Chord Dead Load

Question: 

I have built a 30 ft. x 40 ft. pole barn with nine 30 ft. 2x4 7/12 pitch trusses that are 5 ft. O.C. I am planning to finish out the interior and will attach 7/16 x 4 x 8 OSB sheets to the trusses for my ceiling. Along with this, I will have to add several 2x4 nailers across the 30 ft. span between the trusses to attach the sheeting to. My question is: will these trusses have any problem supporting this ceiling? I am not planning on anything being placed in the section above the ceiling and there will be no walls or supports erected between the ceiling and the floor.

Safety Issues With Design Dead Loads

Question: 

Can I safely install 3/4 in. T&G, OSB on 2x4 trusses that are 24 in. O.C.? My roof was installed over 5/8 in. plywood without clips that have caused a lot of sagging and the shingles need replacing. I want to “fix” it one time and install architecture type shingles, but the garage is 24 ft. wide and 28 ft. long without any load bearing walls. My concern is the weight on the trusses. 5/8 in. plywood weighs 52 lbs. and the OSB weighs 78 lbs. for each 4 ft. x 8 ft. sheet. The roof will require about 84 4 ft. x 8 ft. sheets to cover, which equals about 2,184 lbs.

Repairing Incorrect Floor Truss Installation

Question: 

I have a four-year-old house with glued open-web trusses. Both the truss manufacturer and the builder have admitted to me that the trusses were installed wrong. I have a problem with the suggested repair. I have hired a structural engineer and he suggested installing a 2x10 between each truss and removing the old truss. This would have to take place on both the first and second floors because all the trusses were installed wrong. The manufacturers want to install six strongbacks on each floor, hoping this will tighten them up.

Truss Failure And Repair

Question: 

I am a professional engineer looking for information concerning the failure of metal plate connected wood trusses and methods of repair. I am looking for this information with regard to developing recommendations for the repair of truss systems in the floor structures of two-story multi-family dwellings. I see frequent failure of truss systems of this type in both in bending and due to catastrophic failure at the gussets.

Information On Truss Fire Issues

Question: 

I am trying to develop a guideline for my firefighters regarding initial fire attack in buildings with light-weight trusses. My concern is truss failure, especially when exposed to fire. Is there any information on failure time related to flame impingement? Any information about truss failure – especially in a fire condition would be helpful.

  • « first
  • ‹ previous
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • …
  • next ›
  • last »

Content by Category

  • Business Logistics (511)
    • Employee Training (90)
    • Financial Performance (19)
    • Human Resources (47)
    • Information Technology (31)
    • Market Education (334)
    • Risk Management (82)
    • Workforce Development (94)
  • Construction (217)
    • Bracing & Restraint (48)
    • Building Component Safety Information (BCSI) (54)
    • Cladding Attachments (1)
    • Connections (25)
    • Fall Protection (18)
    • Field Repairs & Alterations (36)
    • Installation (98)
    • Installation Best Practices (70)
    • Jobsite Documents (50)
    • Jobsite Material Handling (15)
    • Jobsite Packages (46)
    • Jobsite Safety (32)
    • National Framers Council (27)
  • Design (261)
    • Building Information Modeling (BIM) (3)
    • Design Documents (84)
    • Energy Codes (9)
    • Engineering (146)
    • Fire Codes (33)
    • Green Building Codes (9)
    • Loads (80)
    • Non-Residential Codes (IBC) (65)
    • Optimization (16)
    • Residential Codes (IRC) (75)
    • Scope of Work (37)
    • Software (15)
  • Manufacturing (128)
    • Automation (9)
    • Delivery (18)
    • Efficiency (26)
    • In-Plant Logistics (16)
    • Quality Control (36)
    • Workplace Safety (58)
  • Materials (106)
    • Lumber (91)
    • MSR Lumber (35)
    • Sheathing (30)
    • Steel (33)
    • Truss Plates (42)
  • Performance (193)
    • Advantages of Components (FAD) (29)
    • Energy Efficiency (12)
    • Fire Resistance (41)
    • Fire Testing (28)
    • Lumber Treatments (27)
    • Moisture Control (22)
    • Product Performance (119)
    • Span Tables (2)
    • Structural Testing (47)
    • Thermal Bridging (2)
  • Products (243)
    • Connectors & Fasteners (30)
    • Engineered Wood Products (34)
    • Floor Trusses (125)
    • Roof Trusses (182)
    • Wall Panels (18)

Facebook LinkedIn

About SBC Magazine

© Truss Publications, Inc. All rights reserved.

SBC Magazine is a publication of the Structural Building Components Association.

Website design by Pushing7