Connectors & Fasteners

Question: 

I am currently undertaking a project dealing with techniques and methods of joining structural timber members. Do you have any available information on timber connections like split rings and design software?

Question: 

We have been specifying laminated veneer lumber (LVL) beams for some time now. The plans usually state, “Beam to be engineered and supplied by truss manufacturer.” What kind of liability issues do I need to watch out for?

Question: 

Girders are trusses specially designed to carry extra loads that are a result of the structural framing members they support. Sometimes a single ply girder truss is insufficient to carry the entire load, so the truss designer designs a multiple-ply girder. This is where identical trusses are built and fastened together to act as one unit to support the load. ANSI/TPI 1 states that girder trusses up to three plies thick can be fastened together with nails. Girders over three plies must be pre-drilled and bolted rather than nailed.

Question: 

I am remodeling a 16-year-old ranch style home. The roof consists of 4/12 26 ft. span trusses, 24 in. O.C., over 2x4 stud walls. What is the recommended means of affixing the top plate of new interior partitions to provide the lateral support needed for the partition? Also, I want to hang a soffit above and overhanging the new kitchen cabinets (recessed lighting placed within). What is the recommended means of attaching the soffit to the underside of the trusses so as not to interfere with the designed movement of the trusses under the variable live load experienced (snow load)?

Question: 

Are there any schematics available on how to horizontally brace a 7/12 pitch roof?

Question: 

The truss industry maintains that the design of truss roof and floor system permanent bracing is the responsibility of the building designer. System permanent bracing covers the entire structure and all bracing element interactions.

Question: 

What is the correct method of attaching scissors trusses to the top plate? I read recently in a trade magazine that this type of truss should be toe-nailed on one end and attached with slotted clips on the other end. According to the article, this is to allow for movement of the truss. We require PE stamped spec sheets from the truss manufacturer to verify trusses meet wind and snow loads. These sheets give bracing requirements but never give recommended attachment requirements.

Question: 

Can you explain drag loads and how to calculate a drag load pertaining to roof trusses?

Question: 

I am a building designer on a salt storage building project. I would like to use metal plate connected wood trusses in the design. What should I specify for the metal connector plates?

Question: 

My company supplied roof trusses for a hotel project. The building inspector shut the project down because the trusses were not designed to account for additional snowdrift loading. The construction plans did not contain any snowdrift loading information. The architect is claiming it is our responsibility to determine drift loading, therefore we must fix the problem. Do you have any documentation to help us dispute the architect’s claim?